| Sign In | Join Free | My chinacomputerparts.com |
|
Brand Name : Star merter
Model Number : CWDZ71CY
Place of Origin : China
Range : -50~200℃, -200~100℃
Output : 4~20mA, 4~20mA HART, RS485, Pt100 (1/3B level)
Power supply : 9~32VDC, 13~32VDC, 15~32VDC, 15~24VDC
Accuracy : 0.25%FS, 0.5%FS
The CWDZ71CY anti-corrosion split explosion-proof temperature transmitter is carefully designed and suitable for measuring the temperature of corrosive liquids and gases. With explosion-proof and HART protocol communication options, cost-effective.
| Basic parameters | |
| Measuring medium | Liquid or gas (compatible with contact materials) |
| Measuring range | -50~200℃,-200~100℃ |
| Measuring element | 1*Pt100(1/3B grade) |
| Response time | 18s (compliant with IEC60751, 0.4m/s wind speed, 10°C step) |
| Stable class=”info” performance | ±0.1%FS/year |
| Explosion-proof type | Intrinsically safe type Ex ia ⅡC T6 Ga (current output only) Dust intrinsically safe type Ex ia IIIC T85℃ Da (current output only) Note/Intrinsically safe must be powered by a safety barrier or intrinsically safe power supply |
| Connection time | 400ms |
| Protection level | Housing IP66 Probe IP68 Note/Protection level refers to the level achieved after electrical connections are complete. |
| Overall weight | With display ≈ 1.4kg Without display ≈ 1.25kg |
| Accuracy level | 0.25%FS, 0.5%FS meter accuracy 0.05%FS (LCD with backlight) |
| Resolution | Analog output 0.02%FS, digital output 0.1℃ |
| Load characteristics | |
| Voltage Type | ≥10kΩ |
| Current Type | No display load ≤ {(Us-7.5) ÷ 0.02} Ω Display load ≤ {(Us-12) ÷ 0.02} Ω (Us = supply voltage) |
| HART Current Type | Load ≤{(Us-12)÷0.02}Ω (Us=supply voltage) |
| Environmental conditions | |
| Ambient temperature | -40~85℃ |
| Ambient humidity | 0%~95%RH (no condensation and no condensation) |
| Electrical protection | |
| Short circuit protection | permanent |
| Reverse polarity protection | No damage, but not working |
| Insulation resistance | ≥100MΩ,500VDC |
| Dielectric strength | 500VAC |
| Output Limitation | |
| 4-20mA | 2.5mA~26mA |
| RS485 | 0~3500/7000 |
| 4-20mAHART | 3.8mA~22mA |
| Overall material | |
| shell | Die-cast aluminum |
| Display window | ≈6mm explosion-proof glass |
| show | LCD display without backlight |
| Probe material | |
| 304 stainless steel seals | Nitrile rubber |
| Cables | PTFE shielded compensation cable (φ3.2mm) |
| Anti-corrosion protection pipe | FEP polyfluorinated ethylene propylene temperature resistance -200~200℃ (contacting the measured medium) |
| Mechanical stability | |
| Vibration resistance | 10g (20…2000Hz) in accordance with IEC60068-2-6 standard |
| Impact resistance | 500g/ms in accordance with IEC60068-2-27 standard |
|
|
CWDZ71CY Anti Corrosion Split Explosion Proof Temperature Transmitter Images |